In Vitro Cytotoxicity Evaluation of Novel Nano-Hydroxyapatite-Silica Incorporated Glass Ionomer Cement

Tahir Yusuf Noorani, Norhayati Luddin, Ismail Ab. Rahman, Saman Malik Masudi

1. Senior Lecturer, Department of Conservative Dentistry, School of Dental Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia. 2. Associate Professor, Department of Prosthodontics, School of Dental Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia. 3. Professor, Department of Biomaterials, School of Dental Sciences, Universiti Sains Malaysia, Kubang Kerian, Kelantan, Malaysia. 4. Professor, Department of Conservative Dentistry, Faculty of Dentistry, Lincoln University College, Petaling jaya, Selangor, Malaysia.

Correspondence Address :
Dr. Norhayati Luddin,
School of Dental Sciences, USM Health Campus, 16150, Kubang Kerian, Kelantan, Malaysia.
E-mail: norhayatiluddin@gmail.com

Abstract

Introduction: Glass Ionomer Cements (GIC) are among the most popular restorative materials, but their use in dentistry is limited due to their physical properties.The hardness of GIC was improved by incorporation of nano-hydroxyapatite-silica into GIC, to expand its applicability.

Aim: To evaluate the cytotoxic effects of nano-hydroxyapatite-silica incorporated glass ionomer cement (HA-SiO2-GIC) on human Dental Pulp Stem Cells (DPSC) and compare it with conventional GIC and resin modified GIC.

Materials and Methods: Material extracts of Fuji IX, Fuji II LC and HA-SiO2-GIC were prepared into seven serial concentrations and applied to 96-well-plates seeded with DPSC. The 96-well-plates were incubated for 24 and 72 hours. The morphology of DPSC was observed under the inverted phase contrast microscope, and the cell viability was determined using MTT assay at both time intervals. Kruskal-Wallis test was performed for statistical analysis.

Results: At maximum concentration, DPSC appeared fewer in number, but the normal spindle morphology was maintained in all groups except for Fuji II LC. At lower concentrations, DPSC appeared normal and more confluent in all groups. The cytotoxic effects of all groups were dose dependent. Fuji IX demonstrated the lowest cytotoxicity, followed by HA-SiO2-GIC. Fuji II LC demonstrated the highest cytotoxicity. The difference was significant between all groups at 200 mg/ml concentration (p<0.05). At concentration <100 mg/ml, cytotoxicity of HA-SiO2-GIC was comparable to that of Fuji IX and lower than that of Fuji II LC.

Conclusion: HA-SiO2-GIC showed a favourable cytotoxicity response and thus holds promise as a future potential restorative material in clinical dentistry.

Keywords

Biocompatibility, Dental pulp stem cells, MTT assay

How to cite this article :

Tahir Yusuf Noorani, Norhayati Luddin, Ismail Ab. Rahman, Saman Malik Masudi. IN VITRO CYTOTOXICITY EVALUATION OF NOVEL NANO-HYDROXYAPATITE-SILICA INCORPORATED GLASS IONOMER CEMENT. Journal of Clinical and Diagnostic Research [serial online] 2017 April [cited: 2017 Apr 25 ]; 11:ZC105-ZC109. Available from
http://jcdr.net/back_issues.asp?issn=0973-709x&year=2017&month=April&volume=11&issue=4&page=ZC105-ZC109&id=9739

DOI and Others

DOI: 10.7860/JCDR/2017/24753.9739


Date of Submission: Oct 12, 2016
Date of Peer Review: Dec 21, 2016
Date of Acceptance: Jan 10, 2017
Date of Publishing: Apr 01, 2017


Financial OR OTHER COMPETING INTERESTS: None.

JCDR is now Monthly and more widely Indexed .
  • PubMed Central® (PMC)New
  • Academic Search Complete Database
  • Chemical Abstracts Service
  • Directory of Open Access Journals (DOAJ)
  • EBSCOhostNew
  • Embase & EMbiology
  • Google Scholar
  • HINARI Access to Research in Health Programme
  • Indian Science Abstracts (ISA)
  • Journal seek Database
  • Open J-Gate
  • Popline (reproductive health literature)
  • SCOPUS
  • www.omnimedicalsearch.com