1. Assistant Professor, Department of Anatomy, Lady Hardinge Medical College, New Delhi, India. 2. Assistant Professor, Department of Anatomy, Lady Hardinge Medical College, New Delhi, India. 3. Director Professor, Department of Anatomy, Lady Hardinge Medical College, New Delhi, India. 4. Director Professor, Department of Anatomy, Lady Hardinge Medical College, New Delhi, India. 5. Statistician, Department of Statistics, ILBS, New Delhi, India. 6. Assistant Professor, Department of Physiology, PGIMER and RML Hospital, New Delhi, India.

Correspondence Address :
Minakshi Verma,
Flat No. 2010, D2, Vasant Kunj, New Delhi-70, Delhi, India.
E-mail: dranmolnaik@gmail.com

Abstract

Introduction: Total hip arthroplasty is a commonly performed surgery now-a-day. There are regional and racial variations in the stature of the population worldwide. So there is always need of population specific data for making best fit prosthesis.

Aim: The present study was done to measure the parameters of proximal femur and to analyse their correlation by using standard statistical analysis.

Materials and Methods: Ninety one dry bones (44 left and 47 right) were used. Femur Head Diameter (FHD), Femur Neck Length (FNL), Femur Neck Diameter (FND), Femur Neck Thickness (FNT), Cervicodiaphyseal Angle (CDA) was directly measured with the help of anthropometric instruments. Femur Head Offset (FHO) and Vertical Offset (VO) were measured in the anteroposterior digital photographs.

Result: Normally distributed variables were compared using Student t-test (Unpaired data) to analyse significant effect. There was a significant difference between right and left side of FND and CDA. Pearson correlation coefficient was used to analyse the relationship among variables. FHO had high correlation with the vertical offset (0.687, p<0.001).

Conclusion: These parameters can be used for designing the prosthesis and plates for hip joint reconstructive surgeries suitable for Indian population.

Keywords

Femur head offset, HIP Prosthesis, Vertical offset

DOI and Others

DOI: 10.7860/JCDR/2017/23955.9210

Date of Submission: Sep 06, 2016
Date of Peer Review: Oct 11, 2016
Date of Acceptance: Nov 09, 2016
Date of Publishing: Feb 01, 2017

Financial OR OTHER COMPETING INTERESTS: None.

JCDR is now Monthly and more widely Indexed .
  • PubMed Central® (PMC)New
  • Academic Search Complete Database
  • Chemical Abstracts Service
  • Directory of Open Access Journals (DOAJ)
  • EBSCOhostNew
  • Embase & EMbiology
  • Google Scholar
  • HINARI Access to Research in Health Programme
  • Indian Science Abstracts (ISA)
  • Journal seek Database
  • Open J-Gate
  • Popline (reproductive health literature)
  • SCOPUS
  • www.omnimedicalsearch.com