Entropy as an Indicator to Measure Depth of Anaesthesia for Laryngeal Mask Airway (LMA) Insertion during Sevoflurane and Propofol Anaesthesia

Saranjit Singh, Sapna Bansal, Garima Kumar, Isha Gupta, J.R. Thakur

1. Associate Professor, Department of Anaesthesia, MMIMSR, Mullana, Haryana, India. 2. Associate Professor, Department of Anaesthesia, MMIMSR, Mullana, Haryana, India. 3. Senior Resident, Department of Anaesthesia, MMIMSR, Mullana, Haryana, India. 4. Postgraduate Student, Department of Anaesthesia, MMIMSR, Mullana, Haryana, India. 5. Professor and Head, Department of Anaesthesia, MMIMSR, Mullana, Haryana, India.

Correspondence Address :
Dr. Sapna Bansal,
289, Durga Colony, Naraingarh-134203, Haryana, India.
E-mail: drsapna10@gmail.com

Abstract

Introduction: Assessment of the depth of anaesthesia is fundamental to the anaesthetic practice. Entropy measurement is an objective monitoring and is of two types- Response Entropy (RE) and State Entropy (SE) indicating analgesic and hypnotic levels during general anaesthesia.

Aim: The aim of our study was to assess the depth of anaesthesia for LMA placement using entropy as a tool. The assessment of entropy as an indicator of depth of anaesthesia in the form of haemodynamic variations and success rate of LMA placement.

Materials and Methods: A prospective study was carried out after ethical committee approval in 100 patients, aged 20-50 years, with ASA grade I and II of either gender undergoing elective surgery lasting less than two hours under general anaesthesia. Anaesthesia was induced with sevoflurane 2.5% and IV propofol at 6 ml/min until entropy value fell from baseline values to 30-40 and then LMA insertion was performed. SE and RE values were noted every 30 seconds for five minutes. Mean blood pressure and heart rate were recorded every minute after induction for 5 minutes.

Results: There was a significant change in RE and SE values within 30 seconds from start of induction. Desired values of RE (40.10±2.52) and SE (39.2±2.47) were achieved at 120 seconds to 150 seconds. Mean dose of propofol used during surgery was 86.5±3.5 mg and mean insertion time was 110±12 seconds Patients in study group had a stable haemodynamics throughout the procedure, (p-value -0.8).

Conclusion: Entropy is a reliable indicator to assess depth of anaesthesia for LMA placement during sevoflurane and propofol anaesthesia.

Keywords

Awareness, Bispectral index, Frontal electromyography, Jaw thrust

How to cite this article :

Saranjit Singh, Sapna Bansal, Garima Kumar, Isha Gupta, J.R. Thakur. ENTROPY AS AN INDICATOR TO MEASURE DEPTH OF ANAESTHESIA FOR LARYNGEAL MASK AIRWAY (LMA) INSERTION DURING SEVOFLURANE AND PROPOFOL ANAESTHESIA. Journal of Clinical and Diagnostic Research [serial online] 2017 July [cited: 2017 Sep 21 ]; 11:UC01-UC03. Available from
http://jcdr.net/back_issues.asp?issn=0973-709x&year=2017&month=July&volume=11&issue=7&page=UC01-UC03&id=10177

DOI and Others

DOI: 10.7860/JCDR/2017/27316.10177


Date of Submission: Feb 06, 2017
Date of Peer Review: Mar 17, 2017
Date of Acceptance: Apr 12, 2017
Date of Publishing: Jul 01, 2017


Financial OR OTHER COMPETING INTERESTS: None.

JCDR is now Monthly and more widely Indexed .
  • PubMed Central® (PMC)New
  • Academic Search Complete Database
  • Chemical Abstracts Service
  • Directory of Open Access Journals (DOAJ)
  • EBSCOhostNew
  • Embase & EMbiology
  • Google Scholar
  • HINARI Access to Research in Health Programme
  • Indian Science Abstracts (ISA)
  • Journal seek Database
  • Open J-Gate
  • Popline (reproductive health literature)
  • SCOPUS
  • www.omnimedicalsearch.com